WOTO

Technical articles and case studies

RF power conversion table: mW and dBm

Reference table converting 0 dBm to 60 dBm into milliwatts and watts, with the logarithmic conversion formula and worked RF engineering examples for amplifier design, radio selection and link budgets.

RF power conversion table: mW and dBm

In RF engineering and wireless communications, transmitter and signal power are commonly expressed in milliwatts (mW) and decibel-milliwatts (dBm). Referenced to 1 mW, dBm expresses absolute power on a logarithmic scale, making it easy to compare and calculate power levels across a very wide dynamic range.

Conversion table (0 to 60 dBm)

dBm Power dBm Power
0 1.0 mW 26 400 mW
1 1.3 mW 27 500 mW
2 1.6 mW 28 640 mW
3 2.0 mW 29 800 mW
4 2.5 mW 30 1.0 W
5 3.2 mW 31 1.3 W
6 4.0 mW 32 1.6 W
7 5.0 mW 33 2.0 W
8 6.0 mW 34 2.5 W
9 8.0 mW 35 3.0 W
10 10 mW 36 4.0 W
11 13 mW 37 5.0 W
12 16 mW 38 6.0 W
13 20 mW 39 8.0 W
14 25 mW 40 10 W
15 32 mW 41 13 W
16 40 mW 42 16 W
17 50 mW 43 20 W
18 64 mW 44 25 W
19 80 mW 45 32 W
20 100 mW 46 40 W
21 128 mW 47 50 W
22 160 mW 48 64 W
23 200 mW 49 80 W
24 250 mW 50 100 W
25 320 mW 60 1000 W

RF power level formula and examples

Output power (or level) is a core specification for amplifiers and wireless transmitters, commonly measured in watts (W), milliwatts (mW) and dBm. Because dBm is referenced to 1 mW, power is converted as follows:

Level (dBm) = 10 × log10(Power / 1 mW)

Worked examples:

  • 5 W = 5000 mW: 10 × log10(5000) ≈ 37 dBm
  • 10 W = 10000 mW: 10 × log10(10000) = 40 dBm
  • 20 W = 20000 mW: 10 × log10(20000) ≈ 43 dBm

As the formula shows, doubling the power increases the level by approximately 3 dBm—a practical rule of thumb in RF amplification, link-budget calculations and wireless system design.